opis produktu
1U Rack mount PLC optical splitter is packaged in a 19-inch rack mount panel. Rack Mount PLC-Planar Lightwave Circuit Splitter is a kind of power splitter based on the integrated quartz baseplate.
Single Mode PLC 1×N and 2×N Splitter divide uniformly optical signals from one or two inputs to multiple outputs, and splitter can be operated in reverse direction to combine multiple signals into fiber or two fibers.
Available with high quality ferrule, professional polishing technology, precise matching for optical endface to achieve more stable transmission and efficient connection.
TAKFLY's PLC optical splitter module has excellent performance parameters. The PLC optical splitter is insensitive to wavelength and has full-band signal transmission from 1260 to 1650 nm.
1U Rack mount PLC optical splitter has the advantages of insensitivity to wavelength, high stability and uniform splitting. It is one of the most important passive devices in optical networks. Widely used in:
- MAN (metropolitan area network)
- LAN (local area network)
- FTTx
| Item | Parameter |
|---|---|
| Type (1×N) | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 |
| Max. Insertion Loss (dB) | 3.9 | 7.2 | 10.3 | 13.5 | 16.8 | 20.3 |
| Max. Uniformity (dB) | 0.8 | 0.8 | 0.8 | 1.0 | 1.5 | 2.0 |
| Min. Return Loss (dB) | 55 |
| Max. PDL (dB) | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
| Type (2×N) | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
| Max. Insertion Loss (dB) | 4.2 | 7.5 | 10.6 | 13.9 | 17.2 | 20.8 |
| Max. Uniformity (dB) | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 |
| Min. Return Loss (dB) | 55 |
| Max. PDL (dB) | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
| Fiber Type | ITU-T G657A1, G657A2 and G652D |
| Operating Wavelength (nm) | 1260~1650 |
| Max. Temperature Stability (dB) | 0.5 (Typical 0.3) |
| Operating Temperature (°C) | -40 ~ +85 |
| Storage Temperature (°C) | -40 ~ +85 |